DXF Power Official LiPo & LiHV Battery Safety Regulations & Professional Manual
Official Factory Manual · Version 2.0 / V3 (10 Languages Edition) DXF POWER · Safety Regulations

Need the official complete documentation for offline use or workshop printing? Download the PDF version below:

↓ Download Official User Manual (PDF · 10-Language Edition)

[CRITICAL SAFETY NOTICE] Lithium Polymer (LiPo / LiHV) batteries pack extremely high energy density. Improper handling, incorrect charging parameters, or physical damage can result in violent fire, explosion, toxic fumes, and severe personal injury. Please read this official manual carefully and follow all safety instructions strictly before use to ensure optimal performance and complete operational safety.

FATAL HAZARD: Never charge a 3.7V Standard LiPo battery in LiHV mode (4.35V/cell). Overcharging will instantly trigger catastrophic thermal runaway, explosion, and fire. Always verify your battery label before setting charger parameters.

Quick Reference Voltage Table: Standard LiPo vs. High-Voltage LiHV

Refer to this quick reference table before every charge and discharge cycle. Standard and LiHV batteries must never be mixed or charged with mismatched parameters.

Parameter / Item Standard LiPo High-Voltage LiHV
Nominal Cell Voltage 3.70 V / cell 3.80 V / cell
Full Charge Cutoff Voltage 4.20 V / cell 4.35 V / cell
Storage Voltage (per cell) 3.80 V – 3.85 V 3.85 V – 3.90 V
Minimum Discharge (Under Load) 3.30 V / cell 3.30 V / cell
Resting Voltage Floor (No Load) 3.50 V / cell 3.50 V / cell
2S Full Charge Voltage 8.40 V 8.70 V
3S Full Charge Voltage 12.60 V 13.05 V
4S Full Charge Voltage 16.80 V 17.40 V
6S Full Charge Voltage 25.20 V 26.10 V
8S Full Charge Voltage 33.60 V 34.80 V
Recommended Charge Rate 1C (Current A = Capacity Ah × 1) 1C (Do not exceed label maximum)
Charging Ambient Temperature 0°C to 45°C (Optimal: 15°C to 30°C)
Discharge Surface Temperature Optimal: 15°C–45°C | Max allowable: ≤ 65°C | Critical alert: 70°C (158°F)
Storage Environment 10°C to 25°C (50°F–77°F), Relative Humidity < 65% RH
Long-Term Inspection Interval Every 2–3 months (60–90 days); re-balance to Storage voltage if < 3.75V/cell

1. Electrical Specifications & Operating Temperature Limits

  • Label Verification: Always inspect the battery label before programming your charger. Verify battery chemistry (Standard 3.7V vs. LiHV 3.8V), cell count (S-rating), capacity, and polarity.
  • Charge Current: We recommend charging at 1C rate to prolong cell lifespan and maintain optimal internal resistance. Never exceed the maximum charge rate specified on the pack.
  • Graded Thermal Regulation: Battery surface temperature must stay within 15°C to 45°C during standard operation. If severe high-load running pushes surface temperatures to 65°C–70°C (150°F–158°F), you must immediately cease operation and let the pack cool completely below 35°C (95°F) before recharging or reusing. Never operate continuously under high thermal stress.

2. Pre-Charge “5-Point Safety Audit” (Fire Prevention Protocol)

  • 1. Physical & Odor Inspection: Carefully inspect the battery packaging for punctures, tears, dents, chemical leakage, swelling, or a sweet chemical odor. Any compromised or deformed battery must never be charged.
  • 2. Mode & Voltage Verification: Use only a certified microcomputer balance charger. Select LiPo Mode (4.20V/cell) for standard packs, and LiHV Mode (4.35V/cell) strictly for high-voltage packs.
  • 3. Manual Cell Count (S-Count) Cross-Check: Even if your charger features automatic cell count detection, always manually verify that the programmed S-count matches the battery (e.g., 2S, 3S, 4S, 6S, 8S). Setting an incorrect S-count leads to catastrophic overcharging.
  • 4. Mandatory Balance & Polarity Check: Both the high-current discharge leads and the JST-XH balance plug must be connected simultaneously. If cell voltage variance exceeds 0.03V, perform a dedicated balance cycle. Never reverse polarity.
  • 5. Fireproof Containment & Active Supervision: Always charge batteries inside an explosion-proof LiPo safe bag or on non-flammable surfaces (concrete or tile). Keep at least 2 meters (6.5 feet) away from combustible materials. Never charge batteries unattended, overnight, or while away.

3. Discharge, Operation & Multi-Pack Rules

  • Post-Crash Quarantine Protocol: Following any drone crash or high-impact RC collision, immediately disconnect the battery and isolate it outdoors in an open, non-flammable area for at least 30 minutes. Internal separator damage can trigger delayed thermal runaway.
  • Cool-Down Before Recharging: Never charge a warm or hot battery (> 35°C) immediately after a run. Allow the pack to rest and cool down to ambient temperature first.
  • Low Voltage Cutoff (LVC): Configure your Electronic Speed Controller (ESC) or flight controller low-voltage cutoff to at least 3.4V per cell under load. Discharging below 3.0V per cell causes permanent chemical damage and fire risk upon recharging.
  • Series and Parallel Multi-Pack Rules: When running multi-battery configurations, only combine packs of the exact same brand, model, batch, capacity, C-rating, and age, with cell voltage variance under 0.03V. Never mix old and new packs or standard LiPo with LiHV.
  • Physical & Electrical Prohibitions: Never short-circuit terminals or allow metallic tools to touch connectors. Never disassemble packs, strip shrink wrap, or solder directly to cell tabs. Never leave packs inside parked vehicles under direct sunlight.

4. Proper Storage, Routine Maintenance & Disposal

  • 72-Hour Storage Rule: If the battery will not be used for more than 3 days (72 hours), use your charger’s Storage Mode to bring cell voltages to 3.80V–3.85V (Standard) or 3.85V–3.90V (LiHV). Never store packs fully charged or depleted below 3.60V/cell.
  • Disconnect All Connectors: Unplug batteries from ESCs, receivers, drones, and voltage alarms before storage to eliminate parasitic drain.
  • Storage Climate: Store in a cool, dry, well-ventilated area between 10°C and 25°C (< 65% RH), away from direct sunlight, heating sources, and children/pets.
  • Periodic Inspection: For long-term storage, inspect cell voltages every 2 to 3 months (60 to 90 days). If any cell drops below 3.75V, run a fresh Storage balance cycle.
  • Safe Neutralization & Disposal: To retire damaged or end-of-life batteries, place the battery outdoors and submerge it in a 5% saltwater bath for 48 hours until completely discharged to 0.0V, then hand it over to a certified electronic recycling facility.

5. Emergency Firefighting & First Aid Protocol

  • Fire Suppression: LiPo fires produce intense jet flames and toxic fumes. Do not rely on standard small water extinguishers. Disconnect power immediately and smother the fire with an ABC Dry Chemical extinguisher, Class D extinguisher, LiPo fire blanket, or dry sand/vermiculite.
  • Chemical First Aid: In case of electrolyte contact with eyes, flush with clean water for at least 15 minutes and seek urgent medical care. Wash skin thoroughly with soap and water. If toxic fumes (such as Hydrogen Fluoride) are inhaled, move to fresh air immediately and seek medical attention.